Abstract
Specular reflectometry and ellipsometry infer film thickness from light reflected in the mirror direction. Light scattered away from that direction by interface roughness has also crossed the film and carries its interference pattern, but its strength depends on roughness statistics that are usually unknown. We ask whether the thickness of a rough film can be retrieved from an off-specular spectrum without prior knowledge of the roughness. Using first-order vector perturbation theory for a film with two rough, correlated interfaces on a layered substrate, we fit directional diffuse spectra with a model in which each interface has a Gaussian power spectral density of unknown amplitude and correlation length and the interfaces have an unknown correlation coefficient (five roughness parameters), and we report a thickness only when a χ² test passes and the profile-likelihood set is a single interval of at most ±5 nm.
At the reference geometry the model identifies the thickness in all 17 noiseless conditions tested, and at 2% noise its 95% set contains the true thickness in 95 of 100 trials. In 1,159 further simulations (16,270 noisy fits) varying film thickness (220–780 nm), illumination and detection angles (0–70°), azimuth, noise (0.25–12% of the peak signal), RMS roughness (0.25–3 nm), correlation length (40–400 nm), interface correlation and spectral sampling, 14,327 fits returned a thickness. Across the film-thickness sweep at 2% noise the reports have a root-mean-square error of 0.63 nm and none missed the true thickness by more than 5 nm. Of the 21 reports that did miss it, 15 occurred when the noise exceeded about 4% of the peak signal (errors up to 7 nm), 5 when the spectrum spanned less than half an interference fringe (500–600 nm) and 1 when the correlation lengths lay between the points of a coarse length grid, a condition that otherwise caused χ² rejections. Non-Gaussian (ABC) roughness was either tolerated or rejected. A flat-film reflectance model fitted to the same diffuse spectra overestimates the thickness by up to 78 nm. Off-specular scattering is therefore a viable route to thickness metrology on rough films when the optical constants, angles, relative spectral calibration and noise covariance are known, the light is purely diffuse, the band covers about one fringe or more and the signal-to-noise ratio is adequate.
Keywords: thin-film metrology; light scattering; interface roughness; power spectral density; BRDF; inverse problems; profile likelihood
Highlights
Off-specular diffuse spectra of a rough film carry its interference fringes: a ±10 nm change alters the spectrum by up to 34% of its peak.
Two correlated Gaussian roughness spectra with unknown amplitudes, lengths and correlation are enough to retrieve the thickness without measuring the roughness first.
Over 220–780 nm at 2% noise, 98.5% of fits report a thickness, with RMSE 0.63 nm and no error above 5 nm.
Failure modes are predictable: high noise widens or withholds the result, a band narrower than half a fringe causes fringe-order errors, and coarse correlation-length grids mostly cause χ² rejections.
Flat-film reflectance models applied to diffuse spectra are biased by tens of nanometres.
1Introduction
Optical thin-film metrology almost always works in the specular direction. Spectroscopic reflectometry and ellipsometry compare the light reflected by a film with a stratified-medium model in which the film thickness enters through the interference of waves reflected at its two boundaries [1]. Interface roughness is a nuisance in that picture: it removes a small fraction of the light from the specular beam and is usually absorbed into an effective surface layer.
The light removed from the specular beam is not lost. A rough interface scatters it into a continuum of directions, and the scattered field of a film is shaped by the same internal standing wave that produces the specular fringes. First-order vector perturbation theory describes this scattering for single surfaces and for stacks of correlated rough interfaces [3, 4, 5]. Angle-resolved scattering from coated optics has long been used to infer interface roughness spectra and their cross-correlation when the layer thicknesses are known [2, 6, 7], and surface power spectral densities (PSDs) are the established language for that characterization [8, 9, 10].
This study reverses the roles. We treat the film thickness as the unknown and the roughness as the nuisance, and ask whether the thickness can be retrieved from a spectrum measured away from the specular direction when nothing is known about the roughness except that it is weak. The difficulty is visible in the structure of the signal: the diffuse reflectance is a sum of optical factors that depend on the thickness, each multiplied by a roughness spectrum that is unknown. A change of roughness can therefore, in principle, imitate a change of thickness. Whether it does so in practice depends on how much freedom the roughness model is given.
We show that a compact roughness model is enough. If each interface is described by a Gaussian PSD of unknown amplitude and correlation length, and the two interfaces by an unknown correlation coefficient, the thickness of a rough film is recovered from a single off-specular spectrum. We call this five-parameter model R2. At the reference geometry it identifies the thickness in all 17 noiseless conditions tested and, at 2% noise, its accepted thickness set contains the true value in 95 of 100 trials. In 1,159 further simulations covering film thickness, illumination and detection geometry, noise, roughness amplitude, correlation length, interface correlation and spectral sampling, the method reports a thickness in 88% of the noisy fits, and only 21 of those 14,327 reports miss the ±5 nm target; its failures are predictable from the signal-to-noise ratio, the width of the spectral band and the fineness of the correlation-length search.
The contributions are: (i) a mechanism, stated in terms of interface factors and the standing wave, for why off-specular spectra encode thickness; (ii) an estimator and decision rule (profile likelihood with an explicit model-rejection test) that needs no prior roughness measurement; (iii) systematic simulations of the conditions under which it works; (iv) tests against non-Gaussian roughness and against discretization of the thickness search; (v) evidence that flat-film reflectance models are no substitute for a scattering model; and (vi) the assumptions a practical instrument must satisfy, with the experiments needed to relax them. All simulations were run with the CAEmble simulation platform and can be reproduced from the retained inputs (Section 9).
2Scattering by a film with two rough interfaces
2.1First-order model
We consider a film of refractive index 1.46 and mean thickness on a 100 nm layer of index 2.10 on an absorbing substrate (), illuminated from air (Fig. 1). The top and bottom film interfaces carry zero-mean, stationary, isotropic height fluctuations and ; the other interfaces are smooth. In first-order (smooth-surface) vector perturbation theory each rough interface radiates as a boundary source whose strength is set by the fields of the flat stack at that interface: the illuminating field and the reciprocal field that a source placed at the detector would produce [5, 11]. Each interface thus contributes a complex Jones amplitude that depends on , the wavelength and the directions, and the ensemble-averaged Mueller BRDF is
where is the Mueller matrix of a Jones matrix, and are the two-dimensional height PSDs of the interfaces and is their cross spectrum. The cross term is signed: correlated interfaces interfere, so the diffuse light is not an incoherent sum of two surfaces. For unpolarized illumination and polarization-insensitive detection the measured BRDF reduces to
with interface factors that depend only on the optics of the flat stack and spectra that depend only on the roughness. The spectra are sampled at the in-plane spatial frequency fixed by the directions and the wavelength,
with incidence angle , detection angle and relative azimuth . Eq. (2) contains the whole inverse problem: the thickness enters only through three computable functions , and the roughness only through three unknown functions sampled along .
2.2Why the diffuse spectrum encodes the thickness
Each interface factor is proportional to the product of the illuminating and reciprocal fields at that interface. Inside the film both fields form standing waves whose nodes move with wavelength (Fig. 2). Changing the thickness places the two interfaces at different phases of these standing waves and changes the relative phase of the two boundary sources. The interface factors therefore oscillate with wavelength and the oscillation pattern shifts with thickness (Fig. 3); the cross factor changes sign, which is the interference between the two interfaces. With the roughness held fixed, a ±10 nm change of a 500 nm film alters the diffuse spectrum by up to 34% of its peak (Fig. 4). The thickness information is present; the question is whether the unknown roughness can imitate it.
2.3Roughness spectra
A Gaussian height correlation gives
with RMS height , correlation length and a real interface correlation . To test robustness we also generate specimens with the ABC (k-correlation) spectrum used in finish analysis and in SCATMECH [10, 11],
normalized so that both models have the same RMS height,
C = 3 is the exponential correlation ; larger C decays faster at high frequency. The reference specimen has nm, nm and , so that and the RMS slope is about 0.02, well inside the smooth-surface regime of first-order theory [9].
2.4Counting unknowns
One detection direction measures one spatial frequency per wavelength. At θi = 45° and θo = 30° the 31 wavelengths from 400 to 700 nm sample 31 frequencies between 2.96 and 5.18 × 105 cycles/m (Fig. 3d). A roughness model that assigns free values to , and at every sampled frequency has three times as many unknowns as data, and a single spectrum cannot separate thickness from roughness under such a model; non-negativity and positive semidefiniteness do not remove the degeneracy. A shape model is required. The Gaussian model has five roughness parameters for the same 31 samples, so the thickness is over-determined; the open question is whether the shape assumption is good enough. Section 5.8 tests that directly.
3Inverse method
3.1Roughness models
We compare three roughness models (Table 1). R2 is the estimator proposed here. R0 and R1 are reference points: R0 is an oracle that is given the true Gaussian spectra, as if the roughness had been measured independently, and R1 assumes that only the top interface is rough. In R2 the spectra are
with , and . For fixed lengths the prediction of Eq. (2) is linear in , and positive semidefiniteness of the 2×2 spectral matrix is the second-order cone . RMS heights are bounded by 3 nm (5 nm in the roughness sweep) and RMS slopes by 0.1. The correlation lengths are searched on a logarithmic grid of 50, 100 and 200 nm for each interface independently (nine pairs); the correlation-length sweep uses five points from 50 to 800 nm.
Model | Spectra | Free roughness parameters | Role |
|---|---|---|---|
R0 | true Gaussian Wtt, Wbb, Wtb | none | oracle: roughness measured independently |
R1 | Gaussian top interface, smooth bottom interface | σt, ℓt | misspecified: one rough interface |
R2 | Gaussian top and bottom, correlated (Eq. 7) | σt, σb, ℓt, ℓb, ρ | proposed estimator |
3.2Profile likelihood and decisions
For every candidate thickness on a grid (200–800 nm in 2 nm steps unless stated) we minimize the whitened residual over the roughness parameters,
where is the measured spectrum, the noise covariance and the cone and bounds above. Each inner problem is a convex second-order-cone program solved with Clarabel [13]; a solver result other than “solved” aborts the fit instead of being accepted. Following the profile-likelihood approach to practical identifiability [12], the accepted thickness set is
Without noise we accept candidates whose residual norm is below 10−10 sr−1. Two decisions are reported for every fit. The model is rejected when the minimum χ² exceeds the 95% quantile of a χ² distribution with as many degrees of freedom as samples (conservative: fitted parameters are not subtracted), or, without noise, when no candidate meets the tolerance. Otherwise the thickness is identified when is a single interval no wider than ±5 nm that does not touch the search boundary. Rejection is the safety mechanism of the method: a rejected fit is not reported as a thickness.
3.3Performance measures
For repeated noisy trials we report the root-mean-square error of the best candidate (RMSE), the median width of , and the share of trials whose accepted set contains the true thickness (coverage), with Wilson score intervals [14]
Each fit ends in one of three outcomes: rejected (the χ² test failed), withheld (the accepted set is wider than ±5 nm or split into several intervals) or reported (a thickness is returned). For reported fits we give the RMSE and the largest error, and we count reports that miss the true thickness by more than the ±5 nm target. Such wrong reports are the failure that matters for a measurement, because they return a wrong number without a warning.
4Simulation design
4.1Reference specimen and measurement
Quantity | Reference value |
|---|---|
Stack | air / film n = 1.46 / fixed layer n = 2.10, 100 nm / substrate n = 3.5 − 0.02i |
Film thickness | 500 nm; the true value lies on the candidate grid unless stated (Section 5.9) |
Roughness | both film interfaces: σ = 1 nm, Gaussian ℓ = 100 nm, ρ = 0.5 |
Geometry | θi = 45°, θo = 30°, φ = 0 (in the plane of incidence), unpolarized |
Spectrum | 400–700 nm in 10 nm steps (31 samples); specular light excluded |
Noise | independent Gaussian; σ given as a percentage of the reference peak BRDF, 1.209 × 10−5 sr−1 |
Search | thickness 200–800 nm on a 2 nm grid (0.5 nm in Sections 5.4 and 5.9); target ±5 nm |
Known exactly | optical constants, fixed-layer thickness, angles, polarization, relative spectral calibration, noise covariance |
4.2Implementation and verification
The forward model and the inversion are implemented in the thin-film-scattering solver (version 1.0.0) of the CAEmble simulation platform. The specimen is a nanometre-scale geometry: film, fixed layer and substrate are axis-aligned boxes with their own optical materials, and the solver reads the layer order and thicknesses from the box boundaries. The response of each candidate thickness is computed on a separate calibration stack that carries no roughness, so the inversion has no access to the true roughness. Jones amplitudes were verified against independent SCATMECH [11] values for bare, single-layer, multilayer and absorbing stacks, normal and oblique incidence and out-of-plane detection, to a relative tolerance of 2 × 10−12 (Appendix A).
4.3Study matrix
The evidence has two parts (Table 3). Local runs reproduce the reference analysis, the non-Gaussian specimens and the flat-film comparison. Remote batches add the sweeps: each family is one experiment whose variables are drawn uniformly at random within the stated ranges, one simulation per draw. Each noisy simulation contains several independent noise realizations of the same specimen, each fitted separately.
Family | Varied | Range | Noise | Simulations | Noisy fits |
|---|---|---|---|---|---|
Local runs | |||||
Reference analysis and controls | Controls and variants (Section 5.1, App. B) | — | 0–5% | 65 | 221 |
Non-Gaussian (ABC) specimens | PSD shape and length grid (Section 5.8) | — | 0–2% | 57 | 980 |
Flat-film comparison | Film thickness, geometry (Section 5.10) | — | 0 | 9 | 0 |
Remote sweeps (one experiment per family, random draws) | |||||
| Film thickness | 220–780 nm | 0 | 100 | 0 |
| Film thickness | 220–780 nm | 2% | 100 | 2000 |
| θi, θo (in-plane) | 0–70° | 0 | 150 | 0 |
| θi, θo (in-plane) | 0–70° | 2% | 150 | 3000 |
| Detection azimuth φ | 0–180° | 2% | 60 | 1200 |
| Noise level (0.5 nm grid) | 0.25–12% | varied | 120 | 2400 |
| Noise level, P/S at two directions | 0.25–12% | varied | 60 | 600 |
| σt, σb | 0.25–3 nm | 2% (absolute) | 120 | 2400 |
| ℓt, ℓb (5-point grid to 800 nm) | 40–400 nm | 2% | 99 | 990 |
| ℓt, ℓb (17-point grid to 800 nm) | 40–400 nm | 2% | 16 | 80 |
| Interface correlation ρ | −1 to 1 | 2% | 80 | 1600 |
| Off-grid thickness, 2 nm grid | 490–510 nm | 2% | 40 | 800 |
| Off-grid thickness, 0.5 nm grid | 490–510 nm | 2% | 40 | 800 |
| Spectral sampling | 400–700 nm / 20 nm | 0 and 2% | 6 | 100 |
| Spectral sampling | 400–700 nm / 30 nm | 0 and 2% | 6 | 100 |
| Spectral sampling | 450–650 nm / 10 nm | 0 and 2% | 6 | 100 |
| Spectral sampling | 500–600 nm / 10 nm | 0 and 2% | 6 | 100 |
5Results
Table 4 summarizes every noisy sweep before the individual results. In most families almost every fit reports a thickness, the reported error stays within two or three grid steps, and the accepted sets cover the true thickness at close to the nominal 95%. The oracle R0, which is given the true roughness, has a lower all-fit RMSE than R2 in all of the 15 families (median ratio R0/R2 0.53); knowing the roughness buys precision, and in the narrowest spectral band it also removes the fringe-order ambiguity that defeats R2 (Section 5.7). The exceptions are informative and are discussed below: high noise (Section 5.4), a coarse correlation-length grid (Section 5.6) and a narrow spectral band (Section 5.7).
Sweep | Fits | Reported | Rejected | Withheld | RMSE | Max |err| | > 5 nm | Coverage |
|---|---|---|---|---|---|---|---|---|
Film thickness 220–780 nm | 2,000 | 98.5% | 1.6% | 0.0% | 0.63 | 2.0 | 0 | 98.2% |
Incidence and detection 0–70° | 3,000 | 98.2% | 1.8% | 0.0% | 0.77 | 4.0 | 0 | 97.6% |
Detection azimuth 0–180° | 1,200 | 98.0% | 2.0% | 0.0% | 1.10 | 4.0 | 0 | 95.3% |
Noise 0.25–12% (one direction) | 2,400 | 57.0% | 1.2% | 41.8% | 1.66 | 7.0 | 12 | 95.9% |
Noise 0.25–12% (P/S, two directions) | 600 | 97.2% | 2.8% | 0.0% | 0.74 | 3.5 | 0 | 97.3% |
RMS height 0.25–3 nm | 2,400 | 96.5% | 1.4% | 2.1% | 0.58 | 6.0 | 3 | 99.2% |
Correlation length 40–400 nm, 5-point grid | 990 | 42.6% | 57.2% | 0.2% | 0.81 | 8.0 | 1 | 93.5% |
Correlation length 40–400 nm, 17-point grid | 80 | 85.0% | 15.0% | 0.0% | 0.94 | 4.0 | 0 | 97.5% |
Interface correlation −1 to 1 | 1,600 | 98.2% | 1.8% | 0.0% | 0.44 | 2.0 | 0 | 98.9% |
Off-grid truth, 2 nm grid | 800 | 98.6% | 1.4% | 0.0% | 0.90 | 2.9 | 0 | 89.4% |
Off-grid truth, 0.5 nm grid | 800 | 98.8% | 1.2% | 0.0% | 0.69 | 2.3 | 0 | 95.8% |
400–700 nm, 20 nm step | 100 | 99.0% | 1.0% | 0.0% | 0.94 | 2.0 | 0 | 99.0% |
400–700 nm, 30 nm step | 100 | 100.0% | 0.0% | 0.0% | 1.39 | 4.0 | 0 | 96.0% |
450–650 nm, 10 nm step | 100 | 100.0% | 0.0% | 0.0% | 0.92 | 2.0 | 0 | 99.0% |
500–600 nm, 10 nm step | 100 | 29.0% | 1.0% | 70.0% | 35.05 | 188.0 | 5 | 92.0% |
5.1Identifiability at the reference geometry
Without noise, the R2 residual falls to zero only at the true thickness (Fig. 5). More than 10 nm away from it the normalized residual ‖r‖²/‖y‖² stays above 1.1%: no other thickness can be imitated by Gaussian roughness. The same holds for every specimen variant and for nine combinations of thickness and angles (Table 5). R1, which allows only the top interface to be rough, is rejected in every case: both interfaces contribute to the signal, and with noise its minimum χ² per sample is 21–2214, far above one. The oracle R0 and the estimator R2 return the same thickness; the largest difference from the truth over the nine controls is 0.000 nm.
Condition | R1 | R0 (oracle) | R2 |
|---|---|---|---|
Reference (ℓ = 100 nm, ρ = 0.5) | rejected | 500 | 500 |
ℓ = 50 nm (both interfaces) | rejected | 500 | 500 |
ℓ = 200 nm (both interfaces) | rejected | 500 | 500 |
ρ = −0.5 | rejected | 500 | 500 |
ρ = 0.9 | rejected | 500 | 500 |
noise 0.5% (one realization) | rejected | 500 | 500 |
noise 2% (one realization) | rejected | 500 | 500–502 |
noise 5% (one realization) | rejected | 500–502 | 500–504 |
9 controls: d = 300/500/700 nm × (5°/10°, 25°/15°, 45°/30°) | 9/9 rejected | 9/9 identified | 9/9 identified |
With 2% noise R2 keeps the true thickness in its accepted set in 95 of 100 single-direction trials (88.8%–97.8%), consistent with the nominal 95% level, with an RMSE of 0.85 nm (Table 6). The oracle reaches 0.35 nm. Knowing the roughness in advance improves the precision, but it is not needed for a correct result once the Gaussian shape is right.
Detection | Model | Truth in set | Wilson 95% | Median |error| (nm) | RMSE (nm) |
|---|---|---|---|---|---|
Unpolarized, one direction | R0 (oracle) | 99/100 | 94.6%–99.8% | 0.0 | 0.35 |
R1 | 0/100 | 0.0%–3.7% | 8.0 | 7.27 | |
R2 | 95/100 | 88.8%–97.8% | 0.0 | 0.85 | |
P/S at two directions | R0 (oracle) | 100/100 | 96.3%–100.0% | 0.0 | 0.00 |
R1 | 0/100 | 0.0%–3.7% | 4.0 | 4.00 | |
R2 | 100/100 | 96.3%–100.0% | 0.0 | 0.00 |
5.2Film thickness from 220 to 780 nm
Across 100 noiseless specimens with thickness drawn between 220 and 780 nm, R2 identified the thickness in 100 and returned the exact value in 100. With 2% noise (2,000 fits on 100 specimens), 98.5% of the fits report a thickness and the rest are rejected by χ². The reported values have an RMSE of 0.63 nm and a largest error of 2 nm, one grid step (Fig. 6); coverage is 98.2% (97.5%–98.7%). The error varies with thickness because the signal does: the worst 40 nm bin, centred at 320 nm, has an RMSE of 1.08 nm.
5.3Illumination and detection geometry
Incidence and detection angles were drawn between 0° and 70° in the plane of incidence. Without noise, every one of the 150 noiseless geometries was identified, including 22 within 5° of the specular condition. With 2% noise, 98.2% of the 3,000 fits report a thickness, with an RMSE of 0.77 nm and a largest error of 4 nm (Fig. 7). The per-geometry RMSE follows the noise relative to the peak diffuse signal of that geometry (Spearman rank correlation 0.81): geometries that collect less scattered light are noisier, not intrinsically ambiguous. Moving the detector out of the plane of incidence changes the sampled frequencies and the interface factors but not the conclusion (Fig. 8): over azimuths of 0–180°, 98.0% of fits report a thickness, with an RMSE of 1.10 nm and a largest error of 4 nm.
5.4Noise and precision
On a 0.5 nm thickness grid the R2 error grows smoothly with noise (Fig. 9, Table 7). The RMSE is 0.34 nm near 0.75% noise and 0.85 nm near 2.5%. The oracle R0 follows the same trend at 55% of the R2 RMSE overall: the error scales with the noise in both models, and not knowing the roughness costs precision rather than correctness. Coverage stays close to the nominal 95% over the whole range and χ² rejections remain rare, as expected when the model is right. What changes with noise is the outcome: the accepted interval widens and, from the 9% bin on, most fits are withheld because their interval exceeds ±5 nm (only 2% are reported in the noisiest bin). Reports that miss the truth by more than 5 nm first appear in the 7.0% bin; all of them are between 5 and 7 nm, i.e. at the edge of the ±5 nm interval that admitted them. Recording P- and S-polarized illumination at two detection directions (30° and 60°) quadruples the data, lowers the RMSE at equal noise by a median factor of 3.0 and removes these failures: across the whole noise range 97.2% of its fits report a thickness and none is off by more than 3.5 nm.
Noise (%) | Fits | RMSE (nm) | Median width (nm) | Truth in set | Reported | Reports > 5 nm |
|---|---|---|---|---|---|---|
Unpolarized, one direction | ||||||
0.38 | 80 | 0.15 | 0.0 | 100.0% | 97.5% | 0 |
0.75 | 80 | 0.34 | 0.5 | 95.0% | 97.5% | 0 |
1.25 | 40 | 0.45 | 1.5 | 95.0% | 100.0% | 0 |
1.75 | 140 | 0.64 | 2.0 | 97.1% | 100.0% | 0 |
2.50 | 120 | 0.85 | 3.0 | 97.5% | 99.2% | 0 |
3.50 | 140 | 1.11 | 4.0 | 97.9% | 99.3% | 0 |
5.00 | 420 | 1.57 | 6.0 | 97.4% | 97.9% | 0 |
7.00 | 340 | 2.36 | 8.5 | 94.7% | 77.9% | 3 |
9.00 | 400 | 3.13 | 11.0 | 95.2% | 20.5% | 6 |
11.00 | 640 | 3.79 | 13.5 | 94.5% | 2.3% | 3 |
P/S at two directions | ||||||
0.38 | 20 | 0.00 | 0.0 | 100.0% | 100.0% | 0 |
0.75 | 60 | 0.06 | 0.0 | 100.0% | 98.3% | 0 |
1.25 | 20 | 0.00 | 0.0 | 100.0% | 95.0% | 0 |
1.75 | 10 | 0.16 | 0.2 | 100.0% | 100.0% | 0 |
2.50 | 80 | 0.30 | 0.5 | 100.0% | 95.0% | 0 |
3.50 | 30 | 0.41 | 1.0 | 96.7% | 100.0% | 0 |
5.00 | 130 | 0.58 | 2.0 | 97.7% | 97.7% | 0 |
7.00 | 90 | 0.85 | 2.5 | 94.4% | 98.9% | 0 |
9.00 | 60 | 0.89 | 3.5 | 98.3% | 91.7% | 0 |
11.00 | 100 | 1.24 | 4.5 | 94.0% | 98.0% | 0 |
5.5Roughness amplitude
In first order the scattered intensity scales with the square of the RMS height, while the noise in this sweep is fixed in absolute terms; halving the roughness quarters the signal-to-noise ratio. With both RMS heights drawn between 0.25 and 3 nm, 96.5% of fits report a thickness, with an RMSE of 0.58 nm (Fig. 10). What matters is the scattered signal, not the roughness of either interface alone: only 3 of the 120 specimens report a thickness in fewer than 90% of their fits, and their noise is 4.7%–16% of their own peak signal; the smoothest specimen (geometric-mean RMS 0.31 nm) reports 0%. Fits that are not reported are withheld as ambiguous (2.1% of all fits in the sweep); their best candidates can be far from the truth (up to 198 nm), which is exactly why they are not reported. Only 3 of the 2,317 reports exceed 5 nm (largest 6 nm), all at a noise level near 5% of the peak signal.
5.6Correlation length and interface correlation
In every sweep so far the true correlation length (100 nm) was one of the grid lengths searched by R2. Drawing both lengths independently between 40 and 400 nm removes that advantage. With the five-point grid (50–800 nm, a factor of two between neighbours) 57% of fits are rejected by χ² (Fig. 11). Rejection depends on how far the true lengths lie from the grid: for the 8 specimens whose lengths both lie within 10% of a grid length it is 16%. A Gaussian of the wrong length cannot reproduce the spectrum within 2% noise, and the χ² test says so; the failure is almost always safe: of 422 reports, 1 exceeded 5 nm (largest 8 nm). A 17-point grid (a factor of 1.19 between neighbours) on 16 specimens of the same kind (80 fits) lowers the rejected share to 15% and reports 85% of fits, with an RMSE of 0.94 nm and a largest error of 4 nm. The correlation lengths therefore have to be searched finely, or optimized continuously, in practice. The interface correlation ρ, drawn between −1 and 1, has no comparable effect: 98.2% of fits report a thickness, with an RMSE of 0.44 nm. The error is essentially zero for anticorrelated interfaces, which scatter more strongly in this geometry, and stays below 1 nm as ρ approaches 1.
5.7Spectral sampling
Sparser sampling of the same 400–700 nm band (16 or 11 samples) and a 450–650 nm band leave the retrieval essentially unchanged (Table 8). A 500–600 nm band does not: it spans less than half an interference fringe of a 500 nm film, only 29% of fits report a thickness, and 5 of those reports are wrong by more than 5 nm, one of them by 188 nm. With 0.87 fringe the retrieval still works; with 0.43 the spectrum no longer fixes the fringe order, and the free Gaussian amplitude and length absorb what would otherwise distinguish neighbouring orders; this is the only failure mode found in which a thickness far from the truth passes all tests. With margin, the band should cover about one fringe or more at the thinnest film of interest.
Band / step (nm) | Samples | Fringes | Noiseless | Fits | Reported | RMSE | Max |err| | > 5 nm |
|---|---|---|---|---|---|---|---|---|
400–700 / 10 (reference*) | 31 | 1.37 | 7/7 | 80 | 100% | 0.63 | 2 | 0 |
400–700 / 20 | 16 | 1.37 | 1/1 | 100 | 99% | 0.94 | 2 | 0 |
400–700 / 30 | 11 | 1.37 | 1/1 | 100 | 100% | 1.39 | 4 | 0 |
450–650 / 10 | 21 | 0.87 | 1/1 | 100 | 100% | 0.92 | 2 | 0 |
500–600 / 10 | 11 | 0.43 | 1/1 | 100 | 29% | 35.05 | 188 | 5 |
5.8Non-Gaussian roughness
The specimens so far were generated with the Gaussian spectra that R2 assumes. To test that assumption, the true roughness was replaced by ABC spectra (Eq. (5)) with C = 3, 4 and 8 and the same RMS height, correlation length and ρ, while R2 was left unchanged. Without noise the best R2 thickness is 500–502 nm for every specimen (Table 9). The shape error leaves a residual of 0.39–2.2% of the signal, growing with C. Within the measured frequency band the fitted Gaussian follows the true spectrum closely (Fig. 12), because only that band enters the data.
Specimen | Length grid | One direction: best | residual | P/S two directions: best | residual |
|---|---|---|---|---|---|
Gaussian control | 50–200 nm | 500 | <10−6% | 500 | <10−6% |
Gaussian control | 50–800 nm | 500 | <10−6% | 500 | <10−6% |
ABC C = 3 | 50–200 nm | 500 | 0.39% | 500 | 0.65% |
ABC C = 3 | 50–800 nm | 500 | 0.39% | 500 | 0.65% |
ABC C = 4 | 50–200 nm | 500 | 0.84% | 500 | 1.4% |
ABC C = 4 | 50–800 nm | 500 | 0.84% | 500 | 1.4% |
ABC C = 8 | 50–200 nm | 502 | 2.2% | 500 | 4.3% |
ABC C = 8 | 50–800 nm | 500 | 0.25% | 500 | 0.33% |
With 2% noise the outcome falls into two regimes (Fig. 13, Table 10). When the shape error is small compared with the noise (C = 3, one direction) χ² cannot see it, and the accepted set still contains the true thickness. When it is large (C = 8, or any C ≥ 4 with P/S at two directions) the fit is rejected. Accepted sets that miss the truth without a rejection occur in at most 2% of ABC trials, against 5/100 for the Gaussian control, and the best-candidate error never exceeds one grid step. With the coarse 50–200 nm length grid the C = 8 specimen was always rejected; widening the grid to 800 nm lets the Gaussian follow the in-band spectrum, and the same trials then include the true thickness. The danger case for a Gaussian model, a confident wrong thickness, did not occur.
Detection | Specimen | Length grid | Fits | Rejected | Truth in set | Truth excluded, not rejected | Max |error| (nm) |
|---|---|---|---|---|---|---|---|
Unpolarized, one direction | Gaussian control | 50–200 nm | 100 | 0% | 95% | 5/100 | 2 |
Unpolarized, one direction | Gaussian control | 50–800 nm | 100 | 0% | 96% | 4/100 | 2 |
Unpolarized, one direction | ABC C = 3 | 50–200 nm | 100 | 0% | 98% | 2/100 | 2 |
Unpolarized, one direction | ABC C = 3 | 50–800 nm | 100 | 0% | 99% | 1/100 | 2 |
Unpolarized, one direction | ABC C = 4 | 50–200 nm | 100 | 60% | 100% | 0/100 | 0 |
Unpolarized, one direction | ABC C = 4 | 50–800 nm | 100 | 58% | 100% | 0/100 | 0 |
Unpolarized, one direction | ABC C = 8 | 50–200 nm | 100 | 100% | 0% | 0/100 | 2 |
Unpolarized, one direction | ABC C = 8 | 50–800 nm | 100 | 28% | 100% | 0/100 | 0 |
P/S at two directions | Gaussian control | 50–200 nm | 50 | 0% | 100% | 0/50 | 0 |
P/S at two directions | Gaussian control | 50–800 nm | 40 | 0% | 100% | 0/40 | 0 |
P/S at two directions | ABC C = 3 | 50–200 nm | 50 | 30% | 100% | 0/50 | 0 |
P/S at two directions | ABC C = 3 | 50–800 nm | 10 | 30% | 100% | 0/10 | 0 |
P/S at two directions | ABC C = 4 | 50–200 nm | 50 | 100% | 100% | 0/50 | 0 |
P/S at two directions | ABC C = 4 | 50–800 nm | 30 | 100% | 100% | 0/30 | 0 |
P/S at two directions | ABC C = 8 | 50–200 nm | 50 | 100% | 100% | 0/50 | 0 |
P/S at two directions | ABC C = 8 | 50–800 nm | 50 | 100% | 100% | 0/50 | 0 |
5.9Discretization of the thickness search
Real films do not have thicknesses on a search grid. With the true thickness drawn continuously between 490 and 510 nm, the 2 nm grid still reports a thickness in 98.6% of fits, with a largest error of 2.9 nm, but its accepted set contains the truth in only 89.4% of fits (Fig. 14). The 95% set is computed on the grid and becomes too narrow when the truth falls between grid points. A 0.5 nm grid restores coverage to 95.8% and lowers the largest reported error to 2.3 nm. The search grid should therefore be finer than the noise-limited precision, or the minimum refined continuously, before an uncertainty is reported.
5.10A flat-film reflectance model is not a substitute
Because the diffuse spectrum oscillates with thickness, it is tempting to fit it with the specular reflectance of a flat film, scaled by a free factor. We fitted the noiseless diffuse spectra of nine specimens (300, 500 and 700 nm, three geometries) with normal-incidence and true-incidence transfer-matrix (TMM) reflectance (Fig. 15, Table 11). The normal-incidence model overestimates the thickness in all nine cases, by +2 to +78 nm, and the true-incidence model by at least +70 nm. The relative residuals are 19–32%, far above any noise level. In one case (700 nm, 45°/30°) the error is only +2 nm while the residual is 28%: an apparently correct thickness is not evidence that the model is right. The bias comes from the operator, not the data; the scattering model fitted to the same spectra recovers every thickness exactly.
True (nm) | θi/θo | Normal-incidence TMM (nm) | True-incidence TMM (nm) | Residual, normal | Residual, true |
|---|---|---|---|---|---|
300 | 5°/10° | 378 | 378 | 22.7% | 22.6% |
300 | 25°/15° | 368 | 386 | 22.8% | 23.7% |
300 | 45°/30° | 348 | 404 | 19.9% | 19.4% |
500 | 5°/10° | 568 | 570 | 29.5% | 29.4% |
500 | 25°/15° | 556 | 582 | 31.7% | 30.9% |
500 | 45°/30° | 520 | 600 | 23.7% | 27.3% |
700 | 5°/10° | 772 | 772 | 22.0% | 22.0% |
700 | 25°/15° | 752 | 788 | 22.3% | 22.9% |
700 | 45°/30° | 702 | 800 (bound) | 27.9% | 31.5% |
6Discussion
6.1When the thickness can be retrieved
The simulations support the central claim: with a two-Gaussian roughness model and an off-specular measurement, the thickness of a rough film can be retrieved without first measuring the roughness. Of the 14,327 thicknesses reported across all sweeps, 21 missed the truth by more than 5 nm: 15 with noise above about 4% of the peak signal, 5 with a band narrower than half a fringe and 1 with correlation lengths between the points of a coarse search grid. Each of these conditions can be checked or avoided in advance. Other conditions were held fixed by the simulations and must be provided by an instrument (Table 12).
Condition | Why it matters | How to meet or test it |
|---|---|---|
Optical constants of all layers and the underlying stack are known | They set the interface factors At, Ab, Atb | Independent ellipsometry of witness samples; fit them as nuisance parameters |
Incidence and detection angles and polarization are known | Angles move both the interference phase and the sampled frequency | Mechanical calibration; angle-perturbation simulations (future work) |
Relative spectral calibration is known | A spectral tilt can imitate part of a thickness change | Calibrate on a diffuse standard |
Noise covariance is known | The χ² test is the safety mechanism | Characterize detector and shot noise; repeat measurements |
Noise below about 4% of the peak signal (one direction) | Above it, reports at the ±5 nm edge become wrong (Section 5.4) | Longer integration, a second direction or P/S illumination |
Band of about one fringe or more | Less than half a fringe leaves the fringe order undetermined (Section 5.7) | Choose the band for the thinnest film of interest |
Fine correlation-length search | A Gaussian of the wrong length is rejected or, rarely, biased (Section 5.6) | Grid steps of ≲ 20% or continuous optimization |
Search grid finer than the precision | Otherwise the reported set is too narrow (Section 5.9) | Fine grid or continuous refinement |
Measured light is purely diffuse | Specular leakage or stray light adds a different spectrum | Beam stops and baffles; add a nonnegative specular term to the model (future work) |
Weak, stationary, isotropic roughness; smooth in-band PSD | First-order theory and the Gaussian shape model | Check 4πσ/λ ≪ 1; test in-band structure (future work) |
6.2Signal level
Scattered light is weak. Fitting the diffuse spectra with a scaled flat-film reflectance gives scale factors of 3.7–5.3 × 10−5 sr−1 for 1 nm RMS roughness, so the diffuse power entering a collection solid angle Ω is roughly that factor times Ω relative to the specular power; for Ω = 10−3 sr the ratio is of order 10−8. Because the signal scales with σ², a film half as rough gives a quarter of the signal, which is where Section 5.5 shows the method starting to withhold results. The noise levels used here are statements about what a given photon budget allows, not about any particular instrument; an experimental assessment has to start from a measured noise floor.
6.3A practical recipe
Model the stack below the film from independent measurements; keep the film thickness as the only optical unknown.
Choose a detection geometry with strong diffuse signal away from the specular direction (Section 5.3) and a band that covers at least about one interference fringe of the thinnest film of interest (Section 5.7).
Fit R2 on a thickness grid finer than the expected precision, and search the correlation lengths finely or continuously (Sections 5.6 and 5.9).
Report a thickness only if the χ² test passes and the accepted set is a single interval within the target; otherwise report a rejection or an ambiguity. If either is frequent, increase the signal or add a second direction or P/S illumination (Section 5.4).
Validate on samples of independently known thickness before relying on the χ² test as a safety mechanism.
6.4Relation to prior work
Angle-resolved scattering from multilayers has mainly been used to infer interface roughness and its cross-correlation from stacks of known thickness [5, 6, 7], and surface PSD analysis to characterize finish [2, 8, 10]. The present work uses the same physics in the opposite direction. The interface factors carry the thickness through the standing wave, while the roughness enters only through smooth spectra sampled along a known frequency curve. A low-dimensional spectral model therefore separates the two; an unconstrained spectrum does not.
7Limitations and future work
The conclusions are computational and hold under the stated conditions. The following studies would extend or test them.
In-band PSD structure. Spectra with peaks or several length scales inside the measured band could be imitated by a different thickness. Generate such specimens (sums of Gaussian or ABC terms) and repeat Section 5.8.
Misspecified noise, angles and spectral calibration. Fit with a noise level, detection angle or spectral tilt different from the truth and measure wrong reports; this requires separating the generating and fitting parameters in the solver.
Fringe-order safety. Combine a band test with a multi-start or two-band check so that sub-fringe spectra are withheld rather than reported.
Specular and stray-light admixture. Add a nonnegative flat-film reflectance term with unknown weight and map identifiability and bias against the admixture ratio.
Finite collection aperture, illumination divergence and spectral bandwidth. Integrate the directional BRDF over the instrument functions and quantify the loss of fringe contrast.
Experimental validation. Measure films of independently known thickness (ellipsometry, cross-section) and compare reported error, χ² per sample and coverage with the simulations.
Several unknown layers. Extend the profile to two thicknesses and test whether a second direction or polarization diversity becomes necessary.
Beyond first order. Larger roughness, anisotropy and multiple scattering, against a rigorous solver.
Numerical stability at long correlation lengths. One simulation of the length sweep stopped because an R2 fit with 800 nm candidate lengths ended with an incomplete solver status (Appendix C); rescaling the cone program should remove this.
8Conclusions
Diffuse light scattered by the interfaces of a rough film carries its thickness through the standing wave inside the film. A five-parameter roughness model, two correlated Gaussian spectra with unknown amplitudes and lengths, is enough to separate that information from the unknown roughness in a single off-specular spectrum. In the simulations reported here the method returned the thickness at nanometre level across film thickness, geometry, roughness amplitude, interface correlation and spectral sampling. It degraded predictably: with rising noise it widened or withheld its result, and its rare misses stayed within a few nanometres of the ±5 nm target; with a coarse correlation-length grid it mostly rejected fits; and with non-Gaussian roughness it either still returned the thickness or rejected the fit. The only large error that passes all tests, a wrong fringe order, occurs only when the band covers less than half a fringe and can be excluded by design. A flat-film reflectance model, in contrast, is biased by tens of nanometres even when it appears to fit. Within the conditions of Section 6.1, off-specular scattering is a viable basis for measuring the thickness of rough films.
9Data availability and reproducibility
All simulations were run with the thin-film-scattering solver 1.0.0 of CAEmble. The local evidence (reference analysis, non-Gaussian specimens, flat-film comparison) is retained with its editable inputs, frozen builds, raw Records and calculation outputs in the reproduction bundle that accompanies this report. Remote sweeps are retained as experiment sources, built artifacts, batch identifiers and per-simulation summaries. The data behind every figure is linked in its caption. A minimal local run is:
caemble doctor
caemble experiment init my-study --example rough-interface-observation-design
caemble experiment check my-study --vars-mode nominal --out my-build
caemble experiment test my-build --out my-result --timeout 300A remote sweep builds many randomized simulations and submits them as one batch:
caemble experiment build my-study --count 100 --vars-mode random --out my-batch
caemble experiment push my-study --artifact my-batch
caemble batch submit my-batch --experiment <experiment-id>AVerification of the forward model
Jones amplitudes against independent SCATMECH values (relative tolerance 2 × 10−12): single rough interface, layered stacks, absorbing layer and substrate, normal and oblique incidence, out-of-plane detection, full-correlation limit; zero roughness gives zero diffuse signal.
Response composition: direct PSD evaluation equals the interface-factor form of Eq. (2).
Polarization: the average of P and S equals unpolarized illumination; results are invariant to joint permutation of conditions and covariance.
Standing wave: single-interface Fresnel limit, agreement with transfer-matrix reflectance, continuity of tangential fields.
ABC spectrum: RMS normalization and the exponential limit at C = 3.
Information separation: removing or altering the specimen roughness does not change the response bank used by the inversion.
Regression: the solver reproduces the earlier implementation of the same model on 74 cases to a relative difference below 7 × 10−11.
BNumerical resolution
Refining the thickness grid and the length grid does not change the noiseless R2 result at the reference geometry. One direction: 1 nm grid 500 nm, 0.5 nm grid 500 nm, five-point length grid 500 nm. P/S at two directions: 500, 500 and 500 nm.
CRun inventory and failures
1,159 remote simulations succeeded and 1 failed; 24 queued simulations of the 17-point length-grid family were cancelled unrun to bound the run time. A simulation fails when any of its convex fits ends with a solver status other than “solved”, which aborts it by design; failed simulations were not re-run with other random draws. The per-simulation inventory with experiment and batch identifiers is part of the reproduction bundle.
Family | Specimen | Cause |
|---|---|---|
| d = 500 nm, ℓ = 389/167 nm | R2 fit at candidate d = 430 nm, lengths 800/800 nm: solver status AlmostSolved |
DSupplementary figures
References
H. G. Tompkins and E. A. Irene (eds.), Handbook of Ellipsometry (William Andrew / Springer, 2005).
J. C. Stover, Optical Scattering: Measurement and Analysis, 3rd ed., SPIE Press Monograph PM224 (SPIE, 2012). https://doi.org/10.1117/3.975276
J. M. Elson, “Light scattering from surfaces with a single dielectric overlayer,” J. Opt. Soc. Am. 66(7), 682–694 (1976).
J. M. Elson, “Infrared light scattering from surfaces covered with multiple dielectric overlayers,” Appl. Opt. 16, 2872 (1977).
J. M. Elson, “Multilayer-coated optics: guided-wave coupling and scattering by means of interface random roughness,” J. Opt. Soc. Am. A 12(4), 729 (1995).
P. Bousquet, F. Flory and P. Roche, “Scattering from multilayer thin films: theory and experiment,” J. Opt. Soc. Am. 71(9), 1115–1123 (1981).
C. Amra, “From light scattering to the microstructure of thin-film multilayers,” Appl. Opt. 32(28), 5481–5491 (1993).
A. Duparré, J. Ferré-Borrull, S. Gliech, G. Notni, J. Steinert and J. M. Bennett, “Surface characterization techniques for determining the root-mean-square roughness and power spectral densities of optical components,” Appl. Opt. 41, 154–171 (2002). https://doi.org/10.1364/AO.41.000154
S. Schröder, A. Duparré, L. Coriand, A. Tünnermann, D. H. Penalver and J. E. Harvey, “Modeling of light scattering in different regimes of surface roughness,” Opt. Express 19(10), 9820–9835 (2011). https://doi.org/10.1364/OE.19.009820
E. L. Church and P. Z. Takacs, “Optimal estimation of finish parameters,” Proc. SPIE 1530, Optical Scatter: Applications, Measurement, and Theory (1991). https://doi.org/10.1117/12.50498
T. A. Germer, SCATMECH: Polarized Light Scattering C++ Class Library, National Institute of Standards and Technology; models Roughness_Stack_BRDF_Model, Correlated_Roughness_Stack_BRDF_Model and ABC_PSD_Function. https://pages.nist.gov/SCATMECH/docs/roughnes.htm
A. Raue, C. Kreutz, T. Maiwald, J. Bachmann, M. Schilling, U. Klingmüller and J. Timmer, “Structural and practical identifiability analysis of partially observed dynamical models by exploiting the profile likelihood,” Bioinformatics 25(15), 1923–1929 (2009). https://doi.org/10.1093/bioinformatics/btp358
P. J. Goulart and Y. Chen, “Clarabel: An interior-point solver for conic programs with quadratic objectives,” arXiv:2405.12762 (2024). https://arxiv.org/abs/2405.12762
E. B. Wilson, “Probable inference, the law of succession, and statistical inference,” J. Am. Stat. Assoc. 22(158), 209–212 (1927). https://doi.org/10.1080/01621459.1927.10502953
Copyright © 2026 Qutat Inc. All rights reserved.
This technical report is the property of Qutat Inc. Reproduction or distribution without permission is prohibited.